Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. odonto ciênc ; 24(4): 420-425, Oct.-Dec. 2009. ilus, graf, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-873969

RESUMO

Purpose: To analyze the stress distribution on a cantilever-fixed partial denture after simulation of maximum mastication loads in order to optimize its design. Methods: A cantilever-fixed partial denture framework was designed in the CAD-CAM system Everest®Kavo v2.0 using two materials, titanium and zirconium, with connectors of 5.28 mm² and 9.05 mm², respectively. A finite element model was built for stress analysis using simulations of mastication load. Results: For zirconia, only the molar cantilever with the smaller connector area and a 0.5-mm fillet exceeded the considered threshold resistance value of 575 MPa. All the other designs yielded resistances below this value. For titanium, only cantilevers with 9.05 mm² connector area and fillets of 1 or 1.4 mm presented stress values inferior to titanium yield strengh. Conclusion: Within the limitations of this study, it can be concluded that titanium cantilever-fixed partial denture frameworks with a 5.28 mm² connector area cannot support maximum mastication loads; frameworks of this material require larger connectors with fillets introduced in the gingival embrasure. Zirconia, however, supports maximum bite forces in most situations with both molar and premolar design cantilevers. Precaution should be taken when dealing with smaller connectors of 5.28 mm².


Objetivo: Analisar a distribuição de tensões em próteses parciais fixas em cantilever após aplicação de cargas simuladoras da mastigação, de forma a otimizar o seu desenho. Metodologia: Obteve-se a infra-estrutura de uma prótese parcial fixa em cantilever no sistema CAD-CAM Everest®Kavo v2.0, considerando dois materiais: titânio e zircônia, com conectores de 5,28 mm² e 9,05 mm², respectivamente. Gerou-se um modelo de elementos finitos, onde foram efetuadas análises de tensões com cargas simuladoras da mastigação. Resultados: Para zircônia, apenas o cantilever molar com área de conector mais reduzida, e concordância de 0,5 mm, excedeu o valor de resistência 575 MPa. Para o titânio, apenas o cantilever de 9,05 mm², com concordâncias de 1 e 1,4 mm, apresentou valores inferiores à tensão do titânio. Conclusão: Dentro das limitações deste estudo pode-se concluir que as infra-estruturas de titânio em cantilever não suportam cargas mastigatórias máximas com uma área de conector de 5,28 mm² e requerem conectores de áreas superiores, com concordâncias introduzidas na embrasura gengival. A zircônia geralmente suporta forças mastigatórias máximas com cantilever molar ou pré-molar. Deve-se ter precaução quando a área dos conectores é reduzida para 5,28 mm².


Assuntos
Prótese Parcial Fixa , Titânio , Zircônio , Resistência à Tração
2.
Rev. odonto ciênc ; 24(3): 323-326, July-Sept. 2009. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-873860

RESUMO

Purpose: To present a case report of a patient with amelogenesis imperfecta rehabilitated with 26 CAD-CAM all-ceramic fully sintered zirconia crowns.Case description: A male subject, 28 year-old, sought dental treatment presenting a clinical condition compatible with amelogenesis imperfecta. All teeth had yellow, brown, and white areas of weak enamel. Composite restorations were present on teeth 14, 16, 24, 25, 26, 27, and 46; dental caries were shown on teeth 36, 37, and 47. Hipersensitivity was reported. The treatment included fully sintered zirconia crowns for all teeth, using a CAD-CAM system. No problems of marginal adaptation of the crowns were detected, and the final results were satisfactory for both the patient and the clinician. Conclusion: The clinical rehabilitation of an amelogenesis imperfecta case is a challenge, and a multidisciplinary approach is required. Zirconia all-ceramics crowns are an excellent option to restore dental aesthetics as the opaque zirconia coping can mask dischromic abutments, and the crowns have biocompatibility and improved physical properties.


Objetivo: Apresentar o caso clínico de um paciente com amelogenesis imperfecta, que foi reabilitado com 26 coroas CAD-CAM de zircônia totalmente sinterizada. Descrição do caso: Um sujeito do sexo masculino, 28 anos, procurou tratamento odontológico apresentando uma condição clínica compatível com amelogenesis imperfecta. Todos os dentes tinham áreas amarelas, marrons e brancas de esmalte enfraquecido. Havia restaurações de resina composta nos dentes 14, 16, 24, 25, 26, 27 e 46; cárie dentária estava presente nos dentes 36, 37 e 47. Relatou-se hipersensibilidade dentária. O tratamento incluiu coroas de zircônia totalmente sinterizada para todos os dentes, usando um sistema CAD-CAM. Nenhum problema de adaptação marginal das coroas foi detectado e os resultados finais foram satisfatórios para ambos o paciente e o clínico. Conclusão: A reabilitação clínica de amelogenesis imperfecta é um desafio e a abordagem multidisciplinar deve ser mandatória. As coroas de zircônia são uma excelente opção para a reabilitação de pacientes com esta anomalia, pois o opaco dos copings de zircônia pode mascarar as diferentes cores dos pilares e o resultado final é esteticamente aceitável, com biocompatibilidade e propriedades físicas superiores.


Assuntos
Humanos , Masculino , Adulto , Amelogênese Imperfeita/terapia , Cerâmica , Coroas , Estética Dentária , Reabilitação Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA